K-Series (High Excitation Force Water Cooled Range)

High excitation force and silent water cooled system for improving test environment K-series, high excitation force water cooled vibration simulating test systems fully developed by IMV.
Advanced performance from the K-series will significantly improve the test environment.

Features

■Silent system design
The water cooling system produces neither the intake nor exhaust sounds that an air cooling system emits.
■Record of significant accomplishments
IMV has been developing the most advanced water cooled system.

Table Insert Pattern (Unit:mm)

Table Insert Pattern

Specifications

System Model K030/
SA4AM
K062/
SA8AM*6
K080/
SA10HAM*6
K100A/
SA14HAM*6
K125A/
SA18HAM*6
Frequency Range(Hz) 0-3000 0-2500 0-2500 0-2500 0-2500
System
Specifications
Rated
Force
Sine(kN) 30.8 61.7 80 100 125
Random
(kN rms)*1
21.5 61.7 80 100 125
Shock(kN) 61.6 123.4 160 200 250
Maximum
Acc.
Sine(m/s2) 1000 1000 1000 1000 1000
Random
(m/s 2 rms)
557 700 700 700 700
Shock
(m/s 2 peak)
2000 2000 2000 2000 2000
Maximum
Vel.
Sine(m/s)*3 1.8 2.0 2.0 2.0 2.0
Shock
(m/s peak)
1.8 2.0 2.0 2.0 2.0
Maximum
Disp
Sine(mmp-p) 51 51 51 51 51
Maximum Travel(mmp-p) 58 60 59 62 62
Maximum Load(kg) 500 1000 1000 2000 2000
Power Requirements
(kVA) *2
49 87 100 150 170
Breaker Capacity
(A) *4
175 350 350 600 600
Vibration
Generator
Model K030 K060 K080 K125A K125A
Armature Mass(Kg) 27 40 60 80 80
Armature Diameter
(φmm)
320 400 446 560 560
Allowable Eccentric
Moment(N・m)
980 980 1550 2450 2450
Dimensions(mm)
W×H×D
1100
x
1090
x
824
1380
x
1085
x
1000
1595
x
1200
x
1050
1776
x
1373
x
1300
1776
x
1373
x
1300
Shaker Body
Diameter(mm)
760 900 1000 1100 1100
Mass(kg) 3000 3700 5000 7000 7000
Power
Amplifier
Model SA4AM-
K30
SA8AM-
K60
SA10HAM-
K80
SA14HAM-
K125A
SA18HAM-
K125A
Maximum Output(kVA) 33 60 100 98 124
Dimensions(mm)
W×H×D
580
x
1950
x
850
1160
x
1950
x
850
1160
x
1950
x
850
1740
x
1950
x
850
1740
x
1950
x
850
Mass(kg) 950 1350 1500 2500 2600
Controller Vibration Controller See Vibration Controller K2
Cooling Cooling Method Shaker:Water cooling/Power Amplifier:Air Cooling
Primary Cooling Water
(ℓ/min)
195 260 390 390 390
Heat
Exchanger
Dimensions
(mm)
W×H×D
580
x
1700
x
850
580
x
1700
x
850
580
x
1700
x
850
580
x
1700
x
850
580
x
1700
x
850
Mass(kg) 400 400 400 400 400
System Model K100LS/
SA16HAM*6
K125LS/
SA20HAM*6
K160/
SA20HAM*6
K200/
SA24HAM*6
K350/
SA36HAM*6
Frequency Range(Hz) 0-2000 0-2000 0-2000 0-2000 0-2000
System
Specifications
Rated
Force
Sine(kN) 100 125 160 200 350
Random
(kN rms)*1
100 125 160 200 315
Shock(kN) 200 250 320 400 700
Maximum
Acc.
Sine(m/s2) 1000 1000 800 1000 1000
Random
(m/s 2 rms)
700 700 560 700 700
Shock
(m/s 2 peak)
2000 2000 1600 2000 2000
Maximum
Vel.
Sine(m/s)*3 2.0 2.0 2.0 2.0 2.0
Shock
(m/s peak)
2.0 2.0 2.4 2.4 3.5
Maximum
Disp
Sine(mmp-p) 100 100 76.2 76.2 76.2
Maximum Travel(mmp-p) 132 132 86 86 94
Maximum Load(kg) 2000 2000 2000 2000 3000
Power Requirements
(kVA) *2
170 190 270 300 325
Breaker Capacity
(A) *4
600 700
Vibration
Generator
Model K125LS K125LS K200 K200 K350
Armature Mass(Kg) 100 100 200 200 350
Armature Diameter
(φmm)
560 560 650 650 760
Allowable Eccentric
Moment(N・m)
2450 2450 4900 4900 4900
Dimensions(mm)
W×H×D
1990
x
1546
x
1370
1990
x
1546
x
1370
2465
x
1908
x
1740
2465
x
1908
x
1740
3020
x
2306
x
2080
Shaker Body
Diameter(mm)
1100 1100 1260 1260 1630
Mass(kg) 8000 8000 16000 16000 37000
Power
Amplifier
Model SA16HAM-
K125LS
SA20HAM-
K125LS
SA20HAM-
K200
SA24HAM-
K200
SA36HAM-
K350
Maximum Output(kVA) 124 155 256 320 400
Dimensions(mm)
W×H×D
1740
x
1950
x
850
1740
x
1950
x
850
2900
x
1950
x
850
2900
x
1950
x
850
4060
x
1950
x
850
Mass(kg) 2600 3300 4850 5000 5450
Controller Vibration Controller See Vibration Controller K2
Cooling Cooling Method Shaker:Water cooling/Power Amplifier:Air Cooling
Primary Cooling Water
(ℓ/min)
390 390 650*5 650*5 590*5
Heat
Exchanger
Dimensions
(mm)
W×H×D
580
x
1700
x
850
580
x
1700
x
850
1050
x
1900
x
800
1050
x
1900
x
800
1200
x
1950
x
1400
Mass(kg) 400 400 600 600 950

Ecology

Eco Specifications

System Model K030/
EM4AM
K062/
EM8AM*6
K080/
EM10HAM*6
K125A/
EM14HAM*6
System
Specifications
Frequency Range(Hz) 0-3000 0-2500 0-2500 0-2500
Rated
Force
Sine(kN) 30.8 61.7 80 100
Random
(kN rms)*1
21.5 61.7 80 100
Shock(kN) 61.6 123.4 160 200
Maximum
Acc.
Sine(m/s2) 1000 1000 1000 1000
Random
(m/s 2 rms)
557 700 700 700
Shock
(m/s 2 peak)
2000 2000 2000 2000
Maximum
Vel.
Sine(m/s)*3 1.8 2.0 2.0 2.0
Shock
(m/s peak)
1.8 2.0 2.0 2.0
Maximum
Disp
Sine
(mmp-p)
51 51 51 51
Maximum Travel(mmp-p) 58 60 59 62
Maximum Load(kg) 500 1000 1000 2000
Power Requirements
(kVA) *2
49 87 100 150
Breaker Capacity
(A) *4
175 350 350 600
Vibration
Generator
Model K030 K060 K080 K125A
Armature Mass(kg) 27 40 60 80
Armature Diameter
(φmm)
320 400 446 560
Allowable Eccentric
Moment(N・m)
980 980 1550 2450
Dimensions(mm)
W×H×D
1100
x
1090
x
824
1380
x
1085
x
1000
1595
x
1200
x
1050
1776
x
1373
x
1300
Shaker Body
Diameter(mm)
760 900 1000 1100
Mass(kg) 3000 3700 5000 7000
Power
Amplifier
Model EM4AM-
K30
EM8AM-
K60
EM10HAM-
K80
EM14HAM-
K125A
Maximum Output
(kVA)
33 60 100 98
Dimensions(mm)
W×H×D
580
x
1950
x
850
1160
x
1950
x
850
1160
x
1950
x
850
1740
x
1950
x
850
Mass(kg) 950 1350 1500 2500
Controller Vibration Controller See Vibration Controller K2
Cooling Cooling Method Shaker:Water Cooling/Amp:Air Cooling
Primary Cooling Water
(ℓ/min)
195 260 390 390*5
Heat
Exchanger
Dimensions
(mm)
W×H×D
580
x
1700
x
850
580
x
1700
x
850
580
x
1700
x
850
580
x
1700
x
850
Mass(kg) 400 400 400 400
System Model K125A/
EM18HAM*6
K125LS/
EM16HAM*6
K125LS/
EM20HAM*6
K200/
EM20HAM*6
K200/
EM24HAM*6
System
Specifications
Frequency Range(Hz) 0-2500 0-2000 0-2000 0-2000 0-2000
Rated
Force
Sine(kN) 125 100 125 160 200
Random
(kN rms)*1
125 100 125 160 200
Shock(kN) 250 200 250 320 400
Maximum
Acc.
Sine(m/s2) 1000 1000 1000 800 1000
Random
(m/s 2 rms)
700 700 700 560 700
Shock
(m/s 2 peak)
2000 2000 2000 1600 2000
Maximum
Vel.
Sine(m/s)*3 2.0 2.0 2.0 2.0 2.0
Shock
(m/s peak)
2.0 2.0 2.0 2.4 2.4
Maximum
Disp
Sine
(mmp-p)
51 100 100 76.2 76.2
Maximum Travel(mmp-p) 62 132 132 86 86
Maximum Load(kg) 2000 2000 2000 2000 2000
Power Requirements
(kVA) *2
170 170 190 270 300
Breaker Capacity
(kVA) *4
600 600 700
Vibration
Generator
Model K125A K125LS K125LS K200 K200
Armature Mass(kg) 80 100 100 200 200
Armature Diameter
(φmm)
560 560 560 650 650
Allowable Eccentric
Moment(N・m)
2450 2450 2450 4900 4900
Dimensions(mm)
W×H×D
1776
x
1373
x
1300
1990
x
1546
x
1370
1990
x
1546
x
1370
2465
x
1908
x
1740
2465
x
1908
x
1740
Shaker Body
Diameter(mm)
1100 1100 1100 1260 1260
Mass(kg) 7000 8000 8000 16000 16000
Power
Amplifier
Model EM18HAM-
K125A
EM16HAM-
K125LS
EM20HAM-
K125LS
EM20HAM-
K200
EM24HAM-
K200
Maximum Output
(kVA)
124 124 155 256 320
Dimensions(mm)
W×H×D
1740
x
1950
x
850
1740
x
1950
x
850
1740
x
1950
x
850
2900
x
1950
x
850
2900
x
1950
x
850
Mass(kg) 2600 2650 3350 4850 5000
Controller Vibration Controller See Vibration Controller K2
Cooling Cooling Method Shaker:Water Cooling/Amp:Air Cooling
Primary Cooling Water
(ℓ/min)
390*5 390*5 390*5 650*5 650*5
Heat
Exchanger
Dimensions
(mm)
W×H×D
580
x
1700
x
850
580
x
1700
x
850
580
x
1700
x
850
1050
x
1900
x
800
1050
x
1900
x
800
Mass(kg) 400 400 400 600 600
  • 1 Random force ratings are specified in accordance with ISO5344 conditions. Please contact IMV or your local distributor with specific test requirements.
  • 2 Power supply: 3-phase 200/220/380/400/415V (K200 and K350 is AC380/400/415V) , 50/60 Hz. A transformer is required for other supply voltages.
  • 3 If the tests (Sweep or Spot) include high velocity, the maximum velocity value should be reduced to 1.4 m/s.
  • 4 Breaker capacity for 200 V
  • 5 Bypass circuit is needed. Please contact IMV or your local distributor for further information.
  • 6 E/L is required for exporting the shaker system of over 50 kN Sine force.
  •  The specification shows the maximum system performance. For long-duration tests, de-rating by up to 70% must be applied. Continuous use at maximum levels may cause failure. Please contact IMV if you use more than 70 %.
  •  In the case of Random vibration test, please set the test definition of the peak value of acceleration waveform to be operated less than the maximum acceleration of Shock.
  •  Frequency range values vary according to sensor and vibration controller.
  •  Armature mass and acceleration may change when chamber is combined.
  •  Mass and dimensions may change for CE-marked systems.