A new standard created by listening to our customers. A wider range of test requirements and higher test specifications.
A-series meets the needs for such a versatile test environment.
Advanced automatic energy saving, high level of functionality and a protected test environment.
A series improves the working environment of vibration testing.
Features
① Improvement of performance
■ Improvement in excitation force
When compared with the conventional i & J series, the A series increases the relative excitation force.
・Increased force per system power requirement
・Increased force per system mass
・Increased force per system size
■ Standard 76.2mmp-p displacement
*Only for A30,A45, A65
A-series has a displacement of 76.2 mmp-p (3 inch stroke) which gives good balance between specification of velocity, acceleration and displacement. This single system can be used in a very wide variety of tests.
■ Increase in frequency range
In addition to the increased displacement of 76.2mmp-p, the maximum frequency range is also increased when compared to the i, and Jseries.
■ Cross-axis acceleration reduction
A series dramatically reduces cross-axis (crosstalk) acceleration (horizontal vibration). Highly accurate testing is achieved.
■ High velocity shock testing *Only for A30,A45, A65
A-series(EM amplifier model)provides a maximuim of 3.5m/s shock velocity testing which has not been possible with standard conventional systems(i,J-series).
② User friendly and Secure
■ Lower power consumption
In comparison with the same class of conventional systems (i,J-series), the A-series achieves lower power consumption. With an automatic energy-saving function increased energy saving is achieved across all force ranges.
■ International safety standards
A-series complies with international safety standards.
② User friendly and Secure
Rapid creation of a test from a set of pre-defined templates conforming to most international test standards.
Remote monitoring of the test status over the internet.
The status of the test, and the amplifier or shaker operation can be viewed on a remote PC using a standard internet browser.
Problems or errors are easily identified.
Home screen
Home screen(Error)
Eco screen
Camera screen
Manual link screen
Table Insert Pattern ‘mm’ pattern (Unit:mm)
Specifications
System Model | A11/SA1HAM | A11/EM1HAM | A22/SA2HAM | A22/EM2HAM | ||
---|---|---|---|---|---|---|
Frequency Range(Hz) | 0-4500*5 | 0-4500*5 | 0-3300 | 0-3300 | ||
System Specifications |
Rated Force |
Sine(kN) | 11 | 11 | 22 | 22 |
Random (kN rms)*1 |
11 | 11 | 22 | 22 | ||
Shock(kN) | 22 | 22 | 44 | 44 | ||
High Velocity Shock(kN) |
– | 16.5 | – | 36 | ||
Maximum Acc. |
Sine(m/s2) | 1000 | 1000 | 1000 | 1000 | |
Random (m/s2 rms) |
630 | 630 | 630 | 630 | ||
Shock (m/s2 peak) |
2000 | 2000 | 2000 | 2000 | ||
High Velocity Shock(m/s2 peak) |
– | 1500 | – | 1636 | ||
Maximum Vel. |
Sine(m/s) | 2.0 | 2.0 | 2.0 | 2.0 | |
Shock (m/s peak) |
2.5 | 2.5 | 2.5 | 2.5 | ||
High Velocity Shock(m/s peak) |
– | 3.5 | – | 3.5 | ||
Maximum Dsp. |
Sine(mmp-p) | 51 | 51 | 51 | 51 | |
High Velocity Shock(mmp-p) |
– | 55 | – | 55 | ||
Maximum Travel(mmp-p) | 64 | 64 | 64 | 64 | ||
Maximum Load(kg) | 200 | 200 | 300 | 300 | ||
Power Requirements (kVA)*2 |
20.4 | 20.4 | 30 | 30 | ||
Breaker Capacity(A) | 75*3 | 75*3 | 100*3 | 100*3 | ||
Vibration Generator |
Model | A11 | A11 | A22 | A22 | |
Armature Mass(Kg) | 11 | 11 | 22 | 22 | ||
Armature Diameter(φmm) | 210 | 210 | 280 | 280 | ||
Allowable Eccentric Moment(N・m) |
294 | 294 | 700 | 700 | ||
Dimensions(mm) WxHxD |
946x827x676 | 946x827x676 | 1038x920x775 | 1038x920x775 | ||
Shaker Body Diameter(mm) |
585 | 585 | 678 | 678 | ||
Mass(kg) | 1080 | 1080 | 1600 | 1600 | ||
Power Amplifier |
Model | SA1HAM-A11 | EM1HAM-A11 | SA2HAM-A22 | EM2HAM-A22 | |
Maximum Output(kVA) | 12 | 12 | 24 | 24 | ||
Dimensions(mm) W×H×D |
580x1950x850 | 580x1950x850 | 580x1950x850 | 580x1950x850 | ||
Mass(kg) | 280 | 330 | 350 | 410 | ||
Controller | Vibration Controller | See Vibration Controller K2 | ||||
Cooling | Cooling Method | Air cooling | ||||
Blower | Dimensions (mm)WxHxD*7 |
606x1315x891 | 708x1421x782 | 707x1531x917 | 707x1531x917 | |
Mass(kg) | 168 | 140 | 215 | 215 | ||
Wattage(kw) | 3.7 | 3.7 | 5.5 | 5.5 | ||
Duct Hose Diameter(φ) |
125 | 125 | 200 | 200 |
System Model | A30/SA3HAM | A30/EM3HAM | A45/SA4HAM | A45/EM4HAM | ||
---|---|---|---|---|---|---|
Frequency Range(Hz) | 0-2600 | 0-2600 | 0-2600 | 0-2600 | ||
System Specifications |
Rated Force |
Sine(kN) | 30 | 30 | 45 | 45 |
Random (kN rms)*1 |
30 | 30 | 45 | 45 | ||
Shock(kN) | 60 | 60 | 90 | 90 | ||
High Velocity Shock(kN) |
– | 50 | – | 80 | ||
Maximaum Acc. |
Sine(m/s2) | 900 | 900 | 900 | 900 | |
Random (m/s2 rms) |
630 | 630 | 630 | 630 | ||
Shock (m/s2 peak) |
1818 | 1818 | 1800 | 1800 | ||
High Velocity Shock(m/s2 peak) |
– | 1515 | – | 1600 | ||
Maximum Vel. |
Sine(m/s) | 2.0 | 2.0 | 2.0 | 2.0 | |
Shock (m/s peak) |
2.5 | 2.5 | 2.5 | 2.5 | ||
High Velocity Shock(m/s peak) |
– | 3.5 | – | 3.5 | ||
Maximum Dsp. |
Sine(mmp-p) | 76.2 | 76.2 | 76.2 | 76.2 | |
High Velocity Shock(mmp-p) |
– | 76.2 | – | 76.2 | ||
Maximum Travel(mmp-p) | 82 | 82 | 82 | 82 | ||
Maximum Load(kg) | 400 | 400 | 600 | 600 | ||
Power Requirements (kVA)*2 |
36 | 36 | 57 | 57 | ||
Breaker Capacity(A) | 125*3 | 125*3 | 200*3 | 200*3 | ||
Vibration Generator |
Model | A30 | A30 | A45 | A45 | |
Armature Mass(Kg) | 33 | 33 | 50 | 50 | ||
Armature Diameter (φmm) |
290 | 290 | 436 | 436 | ||
Allowable Eccentric Moment(N・m) |
850 | 850 | 1550 | 1550 | ||
Dimensions (mm)W×H×D |
1100x1048x840 | 1100x1048x840 | 1232x1215x1040 | 1232x1215x1040 | ||
Shaker Body Diameter(mm) |
725 | 725 | 825 | 825 | ||
Mass(kg) | 2000 | 2000 | 3000 | 3000 | ||
Power Amplifier |
Model | SA3HAM-A30 | EM3HAM-A30 | SA4HAM-A45 | EM4HAM-A45 | |
Maximum Output(kVA) |
31 | 31 | 44 | 44 | ||
Dimensions (mm)WxHxD |
580x1950x850 | 580x1950x850 | 580x1950x850 | 1160x1950x850 | ||
Mass(kg) | 420 | 500 | 900 | 1000 | ||
Controller | Vibration Controller | See Vibration Controller K2 | ||||
Cooling | Cooling Method | Air cooling | ||||
Blower | Dimensions (mm)W×H×D*7 |
707x1531x917 | 707x1531x917 | 1057x1841x1125 | 1294x2123x838 | |
Mass(kg) | 215 | 215 | 375 | 292 | ||
Wattage(kw) | 5.5 | 5.5 | 11 | 11 | ||
Duct Hose Diameter(φ) |
200 | 200 | 250 | 250 |
System Model | A65/SA5HAM*8 | A65/EM5HAM*8 | A74/EM6HAM*8 | A74/EM8HAM*8 | ||
---|---|---|---|---|---|---|
Frequency Range(Hz) | 0-2600*6 | 0-2600*6 | 0-2600*6 | 0-2600*6 | ||
System Specifications |
Rated Force |
Sine(kN) | 65 | 65 | 74 | 74 |
Random (kN rms)*1 |
65 | 65 | 74 | 74 | ||
Shock(kN) | 130 | 130 | 148 | 180 | ||
High Velocity Shock(kN) |
– | 120 | 120 | 160 | ||
Maximum Acc. |
Sine(m/s2) | 900 | 900 | 1000 | 1000 | |
Random (m/s2 rms) |
630 | 630 | 630 | 630 | ||
Shock (m/s2 peak) |
1806 | 1806 | 2000 | 2000 | ||
High Velocity Shock(m/s2 peak) |
– | 1666 | 1621 | 2000 | ||
Maximum Vel. |
Sine(m/s) | 2.0 | 2.0 | 2.0 | 2.0 | |
Shock (m/s peak) |
2.5 | 2.5 | 2.5 | 2.5 | ||
High Velocity Shock(m/s peak) |
– | 3.5 | 3.5 | 3.5 | ||
Maximum Dsp. |
Sine(mmp-p) | 76.2 | 76.2 | 76.2 | 76.2 | |
High Velocity Shock(mmp-p) |
– | 76.2 | 76.2 | 76.2 | ||
Maximum Travel(mmp-p) | 82 | 82 | 82 | 82 | ||
Maximum Load(kg) | 1000 | 1000 | 1000 | 1000 | ||
Power Requirements (kVA)*2 |
83 | 83 | 100 | 100 | ||
Breaker Capacity(A)*3 | 300*3 | 300*3 | 250*4 | 250*4 | ||
Vibration Generator |
Model | A65 | A65 | A74 | A74 | |
Armature Mass(Kg) | 72 | 72 | 74 | 74 | ||
Armature Diameter (φmm) |
446 | 446 | 446 | 446 | ||
Allowable Eccentric Moment(N・m) |
1550 | 1550 | 1550 | 1550 | ||
Dimensions (mm)WxHxD |
1310x1253x1040 | 1310x1253x1040 | 1310x1253x1040 | 1310x1253x1040 | ||
Shaker Body Diameter(mm) |
925 | 925 | 925 | 925 | ||
Mass(kg) | 3500 | 3500 | 3500 | 3500 | ||
Power Amplifier |
Model | SA5HAM-A65 | EM5HAM-A65 | EM6HAM-A74 | EM8HAM-A74 | |
Maximum Output(kVA) |
68 | 68 | 100 | 100 | ||
Dimensions (mm)WxHxD |
580x1950x850 | 1160x1950x850 | 1160x1950x850 | 1160x1950x850 | ||
Mass(kg) | 1000 | 1150 | 1340 | 1850 | ||
Controller | Vibration Controller | See Vibration Controller K2 | ||||
Cooling | Cooling Method | Air cooling | ||||
Blower | Dimensions (mm)WxHxD*7 |
1214x2006x1124 | 1128x2380x899 | 1462x2800x930 | 1462x2800x930 | |
Mass(kg) | 427 | 354 | 320 | 320 | ||
Wattage(kw) | 18.5 | 18.5 | 30 | 30 | ||
Duct Hose Diameter(φ) |
250 | 250 | 250 | 250 |
- 1 Random force ratings are specified in accordance with ISO5344 conditions. Please contact IMV or your local distributor with specific test requirements.
- 2 Power supply: 3-phase 200/220/380/400/415 V (A74 is AC380/400/415 V), 50/60 Hz. A transformer is required for other supply voltages.
- 3 Breaker capacity for AC 200 V.
- 4 Breaker capacity for AC 400 V.
- 5 Above 4000 Hz, the force rolls-off at a rate of -6 dB/oct.
- 6 Above 2000 Hz, the force rolls-off at a rate of -12 dB/oct.
- 7 Spec described above is in case of 60Hz. Dimension is changed in case of 50Hz.
- 8 Export license is required for exporting the shaker system of over 50 kN Sine force.
- The specification shows the maximum system performance. For long-duration tests, de-rating by up to 70 % must be applied. Continuous use at maximum levels may cause failure. Please contact IMV if you use more than 70 %.
- In the case of Random vibration test, please set the test definition of the peak value of acceleration waveform to be operated less than the maximum acceleration of Shock.
- Frequency range values vary according to sensor and vibration controller.
- Mass and dimensions may change for CE-marked systems.
- Armature mass and acceleration may change when chamber is combined.