J-series accommodates high velocity and large displacement testing Long duration shock tests require high velocity and large displacement.
J-series is a high-functionality system that offers usability and durability furnished with functions that accommodate high velocity and large displacement testing.
Features
- ■Expanded maximum test range
- ・Maximum velocity of Sine force: 2.4m/s ・Maximum velocity of Shock force: 4.6m/s ・Maximum displacement: 100mmp-p
- ■Patented upper (armature) support system PS Guide
- Parallel Slope Guide is standard
- ■Low noise
- Optimised design of the air intake based on fluid dynamics has reduced the air-intake noise.
- ■All models can be directly coupled to a climatic test chamber
Table Insert Pattern (Unit:mm)
Specifications
System Model | J230/ SA3M |
J230S/ SA7M |
J240/ SA4M |
J240S/ SA6HAM |
J250/ SA5M |
J250/ SA6M |
J260/ SA7M*6 |
J260S/ SA16HAM*6 |
||
---|---|---|---|---|---|---|---|---|---|---|
Frequency Range(Hz) | 0-3000 | 0-3000 | 0-2400 | 0-2400 | 0-2200 | 0-2200 | 0-2600*4 | 0-2000 | ||
System Specifications |
Rated Force |
Sine(kN) | 16 | 16 | 24 | 24 | 35 | 40 | 54 | 54 |
Random (kN rms)*1 |
16 | 16 | 24 | 24 | 35 | 40 | 54 | 54 | ||
Shock(kN) | 40 | 40 | 55 | 70 | 70 | 80 | 108 | 196 | ||
Maximum Acc. |
Sine(m/s2) | 941 | 888 | 923 | 857 | 777 | 888 | 857 | 857 | |
Random (m/s2 rms) |
658 | 622 | 646 | 600 | 544 | 622 | 600 | 600 | ||
Shock (m/s 2 peak) |
2000 | 2000 | 2000 | 2000 | 1555 | 1777 | 1714 | 2000 | ||
Maximum Vel. |
Sine(m/s) | 2.4 | 2.4 | 2.4 | 2.4 | 2.4 | 2.4 | 2.4 | 2.4 | |
Shock (m/s peak) |
2.4 | 3.5 | 2.4 | 3.6 | 2.4 | 2.4 | 2.4 | 4.6 | ||
Maximum Disp. |
Sine (mmp-p) |
100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | |
Maximum Travel(mmp-p) | 120 | 120 | 120 | 120 | 120 | 120 | 116 | 116 | ||
Maximum Load(kg) | 300 | 300 | 400 | 400 | 600 | 600 | 1000 | 1000 | ||
Power Requirements (kVA)*2 |
28 | 38 | 38 | 52 | 53 | 57 | 86 | 127 | ||
Breaker Capacity (A)*3 |
100 | 150 | 150 | 200 | 200 | 200 | 300 | 500 | ||
Vibration Generator |
Model | J230 | J230S | J240 | J240S | J250 | J250 | J260 | J260S | |
Armature Mass(Kg) | 17 | 18 | 26 | 28 | 45 | 45 | 63 | 63 | ||
Armature Diameter (φmm) |
200 | 200 | 290 | 290 | 440 | 440 | 446 | 446 | ||
Allowable Eccentric Moment(N・m) |
700 | 700 | 850 | 850 | 1550 | 1550 | 1550 | 1550 | ||
Dimensions(mm) W×H×D |
1124 x 1079 x 850 |
1124 x 1079 x 850 |
1234 x 1145 x 890 |
1234 x 1145 x 890 |
1463 x 1301 x 1100 |
1463 x 1301 x 1100 |
1527 x 1319 x 1100 |
1657 x 1319 x 1100 |
||
Shaker Body Diameter(mm) |
630 | 630 | 720 | 720 | 860 | 860 | 920 | 920 | ||
Mass(kg) | 1800 | 1800 | 2400 | 2400 | 3500 | 3500 | 4100 | 5000 | ||
Power Amplifier |
Model | SA3M- J 30 |
SA7M- J 30S |
SA4M- J 40 |
SA6HAM- J 40S |
SA5M- J 50 |
SA6M- J 50 |
SA7M- J 60 |
SA16HAM- J 60S |
|
Maximum Output(kVA) | 23 | 30 | 34 | 40 | 50 | 57 | 70 | 76 | ||
Dimensions(mm) W×H×D |
580 x 1750 x 850 |
580 x 1950 x 850 |
580 x 1750 x 850 |
1160 x 1950 x 850 |
580 x 1950 x 850 |
580 x 1950 x 850 |
580 x 1950 x 850 |
2320 x 1950 x 850 |
||
Mass(kg) | 330 | 500 | 440 | 1200 | 880 | 910 | 1000 | 3200 | ||
Controller | Vibration Controller | See Vibration Controller K2 | ||||||||
Cooling | Cooling Method | Air cooling | ||||||||
Blower | Dimensions (mm) W×H×D*5 |
606 x 1315 x 891 |
606 x 1315 x 891 |
707 x 1531 x 917 |
707 x 1531 x 917 |
1057 x 1841 x 1125 |
1057 x 1841 x 1125 |
1329 x 2141 x 1080 |
1329 x 2141 x 1080 |
|
Mass(kg) | 168 | 168 | 215 | 215 | 375 | 375 | 407 | 407 | ||
Wattage(kw) | 3.7 | 3.7 | 5.5 | 5.5 | 11 | 11 | 15 | 15 | ||
Duct Hose Diameter(φ) |
200 | 200 | 200 | 200 | 250 | 250 | 250 | 250 |
System Model | J230/EM3M | J240/EM4M | J250/EM5M | J250/EM6M | J260/EM7M*6 | ||
---|---|---|---|---|---|---|---|
System Specifications |
Frequency Range(Hz) | 0-3000 | 0-2400 | 0-2200 | 0-2200 | 0-2600*4 | |
Rated Force |
Sine(kN) | 16 | 24 | 35 | 40 | 54 | |
Random (kN rms)*1 |
16 | 24 | 35 | 40 | 54 | ||
Shock(kN) | 40 | 55 | 70 | 80 | 108 | ||
High Velocity Shock (kN)*7 |
30 | 48 | 68 | 77 | 96 | ||
Maximum Acc. |
Sine(m/s2) | 941 | 923 | 777 | 888 | 857 | |
Random (m/s2 rms) |
658 | 646 | 544 | 622 | 600 | ||
Shock (m/s2 peak) |
2000 | 2000 | 1555 | 1777 | 1714 | ||
High Velocity Shock (m/s2 peak)*7 |
1764 | 1846 | 1511 | 1711 | 1523 | ||
Maximum Vel. |
Sine(m/s) | 2.4 | 2.4 | 2.4 | 2.4 | 2.4 | |
Shock (m/s peak) |
2.4 | 2.4 | 2.4 | 2.4 | 2.4 | ||
High Velocity Shock (m/s peak)*7 |
3.5 | 3.5 | 3.5 | 3.5 | 3.5 | ||
Maximum Dsp. |
Sine (mmp-p) |
100 | 100 | 100 | 100 | 100 | |
High Velocity Shock (mmp-p)*7 |
100 | 100 | 100 | 100 | 100 | ||
Maximum Travel(mmp-p) | 120 | 120 | 120 | 120 | 116 | ||
Maximum Load(kg) | 300 | 400 | 600 | 600 | 1000 | ||
Power Requirements (kVA)*2 |
28 | 38 | 53 | 57 | 86 | ||
Breaker Capacity* (A)*3 |
100 | 150 | 200 | 200 | 300 | ||
Vibration Generator |
Model | J230 | J240 | J250 | J250 | J260 | |
Armature Mass(kg) | 17 | 26 | 45 | 45 | 63 | ||
Armature Diameter (φmm) |
200 | 290 | 440 | 440 | 446 | ||
Allowable Eccentric Moment(N・m) |
700 | 850 | 1550 | 1550 | 1550 | ||
Dimensions(mm) W×H×D |
1124 x 1079 x 850 |
1234 x 1145 x 890 |
1463 x 1301 x 1100 |
1463 x 1301 x 1100 |
1527 x 1319 x 1100 |
||
Shaker Body Diameter(mm) |
630 | 720 | 860 | 860 | 920 | ||
Mass(kg) | 1800 | 2400 | 3500 | 3500 | 4100 | ||
Power Amplifier |
Model | EM3M-J30 | EM4M-J40 | EM5M-J50 | EM6M-J50 | EM7M-J60 | |
Maximum Output(kVA) | 23 | 34 | 50 | 57 | 70 | ||
Dimensions(mm) W×H×D |
580 x 1750 x 850 |
580 x 1750 x 850 |
580 x 2100 x 850 |
580 x 2100 x 850 |
1160 x 1950 x 850 |
||
Mass(kg) | 380 | 490 | 930 | 960 | 1400 | ||
Controller | Vibration Controller | See Vibration Controller K2 | |||||
Cooling | Cooling Method | Air cooling | |||||
Blower | Dimensions (mm) W×H×D*5 |
708 x 1421 x 782 |
707 x 1531 x 917 |
1294 x 2123 x 838 |
1294 x 2123 x 838 |
1298 x 2244 x 798 |
|
Mass(kg) | 140 | 215 | 292 | 292 | 305 | ||
Wattage(kw) | 3.7 | 5.5 | 11 | 11 | 15 | ||
Duct Hose Diameter(φ) |
200 | 200 | 250 | 250 | 250 |
- 1 Random force ratings are specified in accordance with ISO5344 conditions. Please contact IMV or your local distributor with specific test requirements.
- 2 Power supply: 3-phase 200/220/380/400/415V, 50/60 Hz. A transformer is required for other supply voltages.
- 3 In case of 200 V
- 4 Above 2000 Hz, the force rolls-of f at a rate of -12 dB/oct.
- 5 Spec described above is in case of 60Hz. Dimension is changed in case of 50Hz.
- 6 E/L is required for exporting the shaker system of over 50 kN Sine force.
- 7 In case of high velocity option
- The specification shows the maximum system performance. For long-duration tests, de-rating by up to 70% must be applied. Continuous use at maximum levels may cause failure. Please contact IMV if you use more than 70 %.
- In the case of Random vibration test, please set the test definition of the peak value of acceleration waveform to be operated less than the maximum acceleration of Shock.
- Frequency range values vary according to sensor and vibration controller.
- Armature mass and acceleration may change when chamber is combined.
- Mass and dimensions may change for CE-marked systems.