SW-74SI Seismic Monitoring System

SI value, the so called “velocity response spectrum”, is one of the standards to express an earthquake’s destructive power against structures. SW-74SI is an advanced model equipped with alarm output to 10-step and SI value output.

SW-74SI spec

Block Diagram

Block Diagram

Features

  • [Fine Visual Display]

    Fine Visual Display

  • [Touch panel type]

    Touch panel type

    Direct operation makes speedy conrirm.

  • [Easy fixing]

    Easy fixing

    U-shaped fixing hole makes easy
    anchor positioning for seismic
    pickup and fixing.

  • [System Calibration Service]

    System Calibration Service

    Calibration system is composed of a compact electrodynamic horizontal table PET-03 and an amplifier with oscillator PET-OA. It can simulate earthquake and enables an easy calibration test.

  • [Compact design]

    Compact design

    By locating pick-up port at a lower place and rounding off the corners, we are able avoid impact to cables from outside.

  • [Water-proof type]

    Water-proof type

    IP67 water proof compliant structure enables installation at
    rainy or dusty places.

  • [History Report Screen]

    History Report Screen

    History up to 50 are saved.

  • [Safety and high accuracy]

    Safety and high accuracy

    This is the most advanced of all
    electrical type. Servo sensors can
    detect acceleration fromO Hz.
    Three units of the servo type
    sensors are equipped in a
    seismometer to detect
    accelerations in 3-axis.

Application
Hazardous material isolation

Hazardous material isolation

2 out of 3 units method of Securing Security

System Comp0sition

System CompsitionOutward Drawing

Outward Drawing

What is “SI value”?

SI value, the so called “velocity response spectrum”, is one of the standards to express an earthquake’s destructive power against structures. Power plants or gas facilities are currently widely using this standard.
Earthquake damage on buildings may differ based on frequency range, or time, and can not be forecast based only on seismic intensity scale or acceleration.

Chart1 Damage situation of each gas dep.Specifications

Processing Unit(SW-74SI)

MODEL SW-74SI
Display Element STN monochrome LCD with touch switch
(back light color: Green/Orange/Red) (Replacement unnecessary)
Display Contents Indicated content switching (Acceleration + Seismic intensity scale/Instrumental
seismic intensity/SI value by internal setting)
Earthquake monitor screen Present time
Earthquake generation screen Earthquake generation time
Maximum value
Alarm hold screen Reset button (Whole reset of alarm/buzzer)
Each setting screen Trigger, Alarm, Date/time
Maintenance screen Pickup test, Earthquake history
Extra Alarm Alarm step : Upper 7-step (ALM4-10) Individual setting (Acceleration /
Instrumental seismic intensity/ SI value. Any setting is possible)
Alarm setting value : 0.1-999.9 (Gal/Instrumental seismic intensity/Kine)
(0.1 step, 0.0 is alarm operation OFF) (Seismic intensity scale alarm is
set by Instrumental seismic intensity value)
Alarm contact : 1a contact (photo MOS relay) Independent COM 2-point
(ALM 1-5, ALM6-10, each 1-point)
Contact rating : 200V-0.65A (AC/DC common, peak value)
Alatm & Buzzer Upper 3-step (ALM1-3) Individual setting,
buzzer 1-point
Alarm setting value : 0.1-999.9 (Gal/Instrumental seismic intensity/Kine)
0.1 step, 0.0 is buzzer operation OFF
(Seismic intensity scale alarm is set by instrumental seismic intensity.)
Alarm & Buzzer
Reset Method
a. External reset terminal (All step reset by no-voltage a contact)
b. Automatic reset by built-in time
c. Reset button the touch panel (Available on the alarm hold screen)
1-9999sec, (Setting interval: 1-sec, 0 is automatic reset OFF)
Fault Alarm [Power failure/System abnormal] 1a/1b contact switching type
Contact rating: 2A 30VDC
(Max. allowance voltage/current : 220VDC/2A)
Serial Output For maintenance (conforms to RS232C) : MC1 (Switching type with screen control)
For external display (conforms to RS422) : MC2
Back-up Unit Backup time ≧10min (ready time), Charging time ≦48hrs
(No function at the operation by optional power 24VDC)
Mounting Method Wall type
Ambient Temperature 0~+50℃
Humidity Range 10~85%RH
Power Supply 100VAC±10%, ≦100VA
24VDC±10%, ≦70W(option)
Outer Dimensions See the outside view
Painted Color Panel: Similar to Munsell 5GY8/0.5
Case: Munsell N6.0
Weight 3kg approx.

Option

Options to expand the function are provided.

Extemal Display ED74(for SW-74SI,SW-74)

Indicates Acceleration value, Seismic intensity scale and Alarm generation time.
“Color display in standard unit is a touch-panel display.
This optional external display is only an indicator without touch-panel function.

Control Unit CU-5

Takes out the alarm when 2-sets among 3-sets operate.
It increases the reliability of control ・ cut-off alarm contact output for seismic monitor.