- Remarkable Actual Results
- Superior type (Alarm Output: Alarm / Trip 2 Steps, DC4~20mA Output, Indicator on the Panel)
- Standard type (Alarm Output: 1 Step – Indicator on the Panel)
- Compatible to all kinds of Pickups
- Stand alone, Panel-implanted, Wall-mounted: Easy Installation
Specifications
Displacement Monitoring
Model | VM-90 MED Superior type | VM-90 MED Standard type | |||||
---|---|---|---|---|---|---|---|
Frequency Range |
|
||||||
Measuring Range(Full scale) | 0~20μmp-p、0~50μmp-p、0~100μmp-p、0~200μmp-p、0~500μmp-p |
||||||
Alarm Step | 2 Steps | 1Step | |||||
DC Output (for Recorder) | 4~20mA(for 0~300Ωload) 1~5V(Load over 100kΩ, 250Ωconnected externally) |
― | |||||
Alarm Action | Activates at Alarm Set and higher level (Time Constant approx.3sec) | ||||||
Alarm setting Extent | Continuously variable over 10~100% of Indicator Full Scale | ||||||
Alarm Contact | 1C Contact for each Alarm | ||||||
Alarm Contact Capacity | 250VAC, 3.0A/24VDC 3.0A (for Resistive Load) | ||||||
Alarm Reset | Automatic | ||||||
Ambient Temp.・Humidity | 0~50℃ 0~85%RH | ||||||
Power Supply | 50/60Hz | ||||||
Power Consumption | Less than 15A | ||||||
Size・Mass | W200×H105×D103 mm(excl. protrusion), 2kg |
*AC200/220V: option *Provide us Measurement Range before shipping
Velocity Monitoring
Model | VM-90 MEV Superior type | VM-90 MEV Standard type | |
---|---|---|---|
Frequency Range | 15~1000Hz +1dB -3dB 20~850Hz ±1dB |
||
Measurement Range (Full Scale) |
0~1mm/s、0~2mm/s、0~5mm/s、0~10mm/s、0~20mm/s、0~50mm/s |
||
Alarm Step | 2 Steps | 1Step | |
DC Output (for Recorder) | 4~20mA(at 0~300Ωload) 1~5V(Load over 100kΩ, 250Ωconnected externally) |
― | |
Alarm Action | Activates at Alarm Set and higher level (Time Constant approx.3sec) | ||
Alarm setting Extent | Continuously variable over 10~100% of Indicator Full Scale | ||
Alarm Contact | 1C Contact for each Alarm | ||
Alarm Contact Capacity | 250VAC, 3.0A/24VDC 3.0A (for Resistive Load) | ||
Alarm Reset | Automatic | ||
Ambient Temp.・Humidity | 0~50℃ 0~85%RH | ||
Power Supply | 50/60Hz | ||
Power Consumption | Less than 15A | ||
Size・Mass | W200×H105×D103 mm(excl. protrusion), 2kg |
*AC200/220V: option *Provide us Measurement Range before shipping
Acceleration Monitoring
Model | VM-90 MEA Superior type | VM-90 MEA Standard type | |
---|---|---|---|
Frequency Range | 10~8000Hz ±3dB 20~500Hz ±1dB |
||
Measuring Range(Full scale) | 0~1m/S2、0~2m/S2、0~5m/S2、0~10m/S2、0~20m/S2 0~50m/S2、0~100m/S2 |
||
Alarm Step | 2 Steps | 1Step | |
DC Output(For recorder) | 4~20mA(at 0~300Ωload) 1~5V(Load over 100kΩ, 250Ωconnected externally) |
― | |
Alarm Operation | Activates at Alarm Set and higher level (Time Constant approx.3sec) | ||
Alarm Setting Range | Continuously variable over 10~100% of Indicator Full Scale | ||
Alarm Contact | 1C Contact for each Alarm | ||
Alarm Contact Capacitance | 250VAC, 3.0A/24VDC 3.0A (for Resistive Load) | ||
Alarm Reset | Automatic | ||
Ambient Condition | 0~50℃ 0~85%RH | ||
Power Supply | AC +10%, -15%, 50/60Hz | ||
Power Consumption | Less than 15A | ||
Dimensions & Weight | W200×H105×D103 mm(excl. protrusion), 2kg |
*AC200/220V: option *Provide us Measurement Range before shipping