Vibration Switch (VM-90M)

  • Remarkable Actual Results
  • Superior type (Alarm Output: Alarm / Trip 2 Steps, DC4~20mA Output, Indicator on the Panel)
  • Standard type (Alarm Output: 1 Step – Indicator on the Panel)
  • Compatible to all kinds of Pickups
  • Stand alone, Panel-implanted, Wall-mounted: Easy Installation

Specifications

Displacement Monitoring

Model VM-90 MED Superior type VM-90 MED Standard type
Frequency Range
Medium
freq.type
15~500Hz +0.5dB -3dB
15~500Hz ±0.5dB
Low
freq.type
5~300Hz +0.5dB -3dB
10~300Hz ±0.5dB
Measuring Range(Full scale)
0~20μmp-p、0~50μmp-p、0~100μmp-p、0~200μmp-p、0~500μmp-p
Alarm Step 2 Steps 1Step
DC Output (for Recorder) 4~20mA(for 0~300Ωload)
1~5V(Load over 100kΩ, 250Ωconnected externally)
Alarm Action Activates at Alarm Set and higher level (Time Constant approx.3sec)
Alarm setting Extent Continuously variable over 10~100% of Indicator Full Scale
Alarm Contact 1C Contact for each Alarm
Alarm Contact Capacity 250VAC, 3.0A/24VDC 3.0A (for Resistive Load)
Alarm Reset Automatic
Ambient Temp.・Humidity 0~50℃ 0~85%RH
Power Supply 50/60Hz
Power Consumption Less than 15A
Size・Mass W200×H105×D103 mm(excl. protrusion), 2kg

*AC200/220V: option *Provide us Measurement Range before shipping

Velocity Monitoring

Model VM-90 MEV Superior type VM-90 MEV Standard type
Frequency Range 15~1000Hz +1dB -3dB
20~850Hz ±1dB
Measurement Range
(Full Scale)

0~1mm/s、0~2mm/s、0~5mm/s、0~10mm/s、0~20mm/s、0~50mm/s
Alarm Step 2 Steps 1Step
DC Output (for Recorder) 4~20mA(at 0~300Ωload)
1~5V(Load over 100kΩ, 250Ωconnected externally)
Alarm Action Activates at Alarm Set and higher level (Time Constant approx.3sec)
Alarm setting Extent Continuously variable over 10~100% of Indicator Full Scale
Alarm Contact 1C Contact for each Alarm
Alarm Contact Capacity 250VAC, 3.0A/24VDC 3.0A (for Resistive Load)
Alarm Reset Automatic
Ambient Temp.・Humidity 0~50℃ 0~85%RH
Power Supply 50/60Hz
Power Consumption Less than 15A
Size・Mass W200×H105×D103 mm(excl. protrusion), 2kg

*AC200/220V: option *Provide us Measurement Range before shipping

Acceleration Monitoring

Model VM-90 MEA Superior type VM-90 MEA Standard type
Frequency Range 10~8000Hz ±3dB
20~500Hz ±1dB
Measuring Range(Full scale)
0~1m/S2、0~2m/S2、0~5m/S2、0~10m/S2、0~20m/S2 0~50m/S2、0~100m/S2
Alarm Step 2 Steps 1Step
DC Output(For recorder) 4~20mA(at 0~300Ωload)
1~5V(Load over 100kΩ, 250Ωconnected externally)
Alarm Operation Activates at Alarm Set and higher level (Time Constant approx.3sec)
Alarm Setting Range Continuously variable over 10~100% of Indicator Full Scale
Alarm Contact 1C Contact for each Alarm
Alarm Contact Capacitance 250VAC, 3.0A/24VDC 3.0A (for Resistive Load)
Alarm Reset Automatic
Ambient Condition 0~50℃ 0~85%RH
Power Supply AC +10%, -15%, 50/60Hz
Power Consumption Less than 15A
Dimensions & Weight W200×H105×D103 mm(excl. protrusion), 2kg

*AC200/220V: option *Provide us Measurement Range before shipping

Outward Size