VSH-Series (Wide Frequency Band Type)

Suitable for Bench-top SimulationSuitable for various types of bench-top testing.

Vibration controller: Enables complicated vibration tests being coupled with the vibration controller.

Table Insert Pattern (Unit: mm)

Table Insert Pattern

Specifications

System Model VSH-100-M2 VSH-100R-M2
System
Specifications
Frequency Range (Hz) 0-8000 0-10000
Rated
Force
Sine (N) 980 980
Random (Nrms) 392 392
Shock (N) 980 980
Maximum Acceleration (m/s2) *1 980 980
Maximum Velocity (m/s) 0.8 0.8
Maximum Displacement (mmp-p) 10 10
Maximum Load (kg) 30 Up to the Spring Constant
Power Requirements (kVA) *2 4.0 4.0
Vibration
Generator
Model VEH-100 VEH-100R
Armature Support Method Roller/Air suspension Flexures/Rollers
Armature Support Spring Constant
(kN/m)
49
Armature Mass 1.0 1.0
Armature Diameter (φmm) 96 96
Dimensions (mm)W×H×D φ390xH306 φ390xH306
Mass (kg) 120 120
Power
Amplifier
Model VAH-M2 VAH-M2
Maximum Output (kVA) 1.5 1.5
Dimensions (mm)W×H×D 580x1750x850 580x1750x850
Mass (kg) 230 230
Cooling Cooling Method Air cooling
Blower Dimensions (mm)W×H×D 247x252x284 247x252x284
Mass (kg) 10.5 10.5
  • 1 Spec described above is under bare table condition. The maximum acceleration decreases when accelerometer and mounting adapter are mounted.
  • 2 Power supply : three-phase AC200 V±10 %, 50 / 60 Hz (Voltage down transformer [step-down transformer] is required for other voltage)
  •  The specification shows the maximum system performance. For long-duration tests, de-rating by up to 70 % must be applied. Continuous use at maximum levels may cause failure. Please contact IMV if you use more than 70 %.
  •  Frequency range values vary according to sensor and vibration controller.