Suitable for Bench-top SimulationSuitable for various types of bench-top testing.
Vibration controller: Enables complicated vibration tests being coupled with the vibration controller.
Table Insert Pattern (Unit: mm)
Specifications
System Model | VSH-100-M2 | VSH-100R-M2 | ||
---|---|---|---|---|
System Specifications |
Frequency Range (Hz) | 0-8000 | 0-10000 | |
Rated Force |
Sine (N) | 980 | 980 | |
Random (Nrms) | 392 | 392 | ||
Shock (N) | 980 | 980 | ||
Maximum Acceleration (m/s2) *1 | 980 | 980 | ||
Maximum Velocity (m/s) | 0.8 | 0.8 | ||
Maximum Displacement (mmp-p) | 10 | 10 | ||
Maximum Load (kg) | 30 | Up to the Spring Constant | ||
Power Requirements (kVA) *2 | 4.0 | 4.0 | ||
Vibration Generator |
Model | VEH-100 | VEH-100R | |
Armature Support Method | Roller/Air suspension | Flexures/Rollers | ||
Armature Support Spring Constant (kN/m) |
– | 49 | ||
Armature Mass | 1.0 | 1.0 | ||
Armature Diameter (φmm) | 96 | 96 | ||
Dimensions (mm)W×H×D | φ390xH306 | φ390xH306 | ||
Mass (kg) | 120 | 120 | ||
Power Amplifier |
Model | VAH-M2 | VAH-M2 | |
Maximum Output (kVA) | 1.5 | 1.5 | ||
Dimensions (mm)W×H×D | 580x1750x850 | 580x1750x850 | ||
Mass (kg) | 230 | 230 | ||
Cooling | Cooling Method | Air cooling | ||
Blower | Dimensions (mm)W×H×D | 247x252x284 | 247x252x284 | |
Mass (kg) | 10.5 | 10.5 |
- 1 Spec described above is under bare table condition. The maximum acceleration decreases when accelerometer and mounting adapter are mounted.
- 2 Power supply : three-phase AC200 V±10 %, 50 / 60 Hz (Voltage down transformer [step-down transformer] is required for other voltage)
- The specification shows the maximum system performance. For long-duration tests, de-rating by up to 70 % must be applied. Continuous use at maximum levels may cause failure. Please contact IMV if you use more than 70 %.
- Frequency range values vary according to sensor and vibration controller.